==Information on NPS==
 +
*[https://wiki.jlab.org/cuawiki/index.php/Documents#Calorimeter|NPS Calorimeter page]
 +
*radiation for NPS: a few 100s/10s rad/hour @ (20-30) deg range with magnet off/on;
 +
*typical gain of PMT at operation: 1E3; Preamp: x12
 +
*In the active base design, [https://www.vsl.cua.edu/cua_phy/images/a/ac/NSS2012_JLAB.pdf|poster by Vladimir Popov], Fig.6 shows gain vs. LED frequency, show up to 2-3 increase in gain for certain rates.
 +
*In [http://www.vsl.cua.edu/cua_phy/images/c/cb/Hamlet.pdf|Hamlet's report] at the 2013 Hall C meeting, slide 12, gain changes at > 50 kHz; base tested during Qweak up to 150 krad
 +
 +
==Simulation Update==
 +
*Ye now has SoLID vs. Beamtest Edep plots. What about radiation dose?
 +
 +
==Discussions==
 +
*Xiaochao: Should we start considering active base design?
 +
*JP: LED test is different from beam, need to be cautious about using LED test results
 +
*Paul S.: passive base has its own advantages, should wait for more lessons from NPS
 +
*JP: If we need more tests, need to coordinate with Simona on effort planning
 +
*Zhiwen/Xinzhan: Weizhi looked at 82-deg data GEM rates. Now will look at 18 deg data.
 +
*Xinzhan is testing methods for Fermilab GEM test data
 +
*Xiaochao will email Rakitha about finding readout method for LASPD
  
 
==Discussion with SDU+THU groups==
 
==Discussion with SDU+THU groups==
(Xiaochao, Zhihong, Cunfeng)
+
(Xiaochao, Zhihong, Cunfeng, 8pm ET)
 
* Cunfeng: SDU Ye Tian soldered the resistors on the PMT for the two SDU Shower modules. Zhihong: For the THU module, should have used the base directly from Hamamatsu
 
* Cunfeng: SDU Ye Tian soldered the resistors on the PMT for the two SDU Shower modules. Zhihong: For the THU module, should have used the base directly from Hamamatsu
 
*Zhihong: asked to study peak integral vs. integration time window (pileup and gain change will show up differently)
 
*Zhihong: asked to study peak integral vs. integration time window (pileup and gain change will show up differently)
 
*Cunfeng:
 
*Cunfeng:
**Showed test of Chunhui fiber fusion using 1 of the many methods, see slide: [Fiberfuse-testOct12.ppt|https://solid.jlab.org/wiki/index.php/File:Fiberfuse-testOct12.ppt]
+
**Showed test of Chunhui fiber fusion using 1 of the many methods, see slide: [https://solid.jlab.org/wiki/index.php/File:Fiberfuse-testOct12.ppt|Fiberfuse-testOct12.ppt]
 
**As can be seen from the slide, the light transfer efficiency is 15% using the method.  On slide 8, we have compairson of different fusing method but the highest is only 60%.  This is comparable to fiber bundle (basically, the geometrical matching factor between two random circles is already 60%). And so we should go back to our baseline design using Fujikura DDK fiber connectors.   
 
**As can be seen from the slide, the light transfer efficiency is 15% using the method.  On slide 8, we have compairson of different fusing method but the highest is only 60%.  This is comparable to fiber bundle (basically, the geometrical matching factor between two random circles is already 60%). And so we should go back to our baseline design using Fujikura DDK fiber connectors.   
 
*MCPPMT: Zhihong said he sent one to Alexandre.
 
*MCPPMT: Zhihong said he sent one to Alexandre.

Latest revision as of 19:53, 23 October 2023

Information on NPS

  • Calorimeter page
  • radiation for NPS: a few 100s/10s rad/hour @ (20-30) deg range with magnet off/on;
  • typical gain of PMT at operation: 1E3; Preamp: x12
  • In the active base design, by Vladimir Popov, Fig.6 shows gain vs. LED frequency, show up to 2-3 increase in gain for certain rates.
  • In report at the 2013 Hall C meeting, slide 12, gain changes at > 50 kHz; base tested during Qweak up to 150 krad

Simulation Update

  • Ye now has SoLID vs. Beamtest Edep plots. What about radiation dose?

Discussions

  • Xiaochao: Should we start considering active base design?
  • JP: LED test is different from beam, need to be cautious about using LED test results
  • Paul S.: passive base has its own advantages, should wait for more lessons from NPS
  • JP: If we need more tests, need to coordinate with Simona on effort planning
  • Zhiwen/Xinzhan: Weizhi looked at 82-deg data GEM rates. Now will look at 18 deg data.
  • Xinzhan is testing methods for Fermilab GEM test data
  • Xiaochao will email Rakitha about finding readout method for LASPD

Discussion with SDU+THU groups

(Xiaochao, Zhihong, Cunfeng, 8pm ET)

  • Cunfeng: SDU Ye Tian soldered the resistors on the PMT for the two SDU Shower modules. Zhihong: For the THU module, should have used the base directly from Hamamatsu
  • Zhihong: asked to study peak integral vs. integration time window (pileup and gain change will show up differently)
  • Cunfeng:
    • Showed test of Chunhui fiber fusion using 1 of the many methods, see slide: [1]
    • As can be seen from the slide, the light transfer efficiency is 15% using the method. On slide 8, we have compairson of different fusing method but the highest is only 60%. This is comparable to fiber bundle (basically, the geometrical matching factor between two random circles is already 60%). And so we should go back to our baseline design using Fujikura DDK fiber connectors.