<pre>
 
  
20200814_140522
 
scaler ped run
 
only board 1 at fiber 0, no PMT 
 
 
20200814_191511
 
scaler dark run
 
only board 1 at fiber 0, no PMT       
 
 
20200815_195653
 
scaler ped run
 
all 5 boards (1,4,5,6,7) at fiber 0-4
 
no PMT 
 
 
20200815_203418
 
scaler dark run
 
all 5 boards (1,4,5,6,7) at fiber 0-4
 
no PMT 
 
 
== change board 1 to board 3 ============================
 
 
20200816_151736
 
scaler ped run
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
no PMT 
 
 
20200816_162216
 
scaler ped run
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV off
 
 
20200816_163345
 
scaler ped run
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.91kV
 
 
20200816_163948
 
scaler ped run
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.91kV, LED 1khz
 
 
20200816_170121
 
scaler dark run
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.91kV
 
 
20200816_175501  --------------------------------------(good ped run)
 
scaler ped run
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV off
 
 
=== change HV powersupply =============
 
 
20200816_202845
 
scaler dark run (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV ~1kV
 
 
20200816_205553
 
scaler dark run (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV ~1kV
 
 
20200816_210149
 
scaler dark run (150 - 250 scan)(scan interval 2s)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV ~1kV
 
 
20200816_221706
 
scaler dark run (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV ~0.5kV
 
 
20200816_222918
 
scaler dark run (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV ~0.7kV
 
 
20200816_231054
 
scaler dark run (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV ~0.7kV
 
 
20200817_104645
 
scaler dark run (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV ~0.7kV
 
 
=== change HV powersupply =============
 
20200817_111943
 
scaler dark run (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 1kV
 
 
=== fix light leak  =============
 
20200817_113028
 
scaler dark run (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 1kV
 
 
20200817_113442
 
scaler ped run
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 1kV
 
 
20200817_114237
 
scaler ped run
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV off
 
 
20200817_114729
 
scaler dark run (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.7kV
 
 
=== put cap on pmt  =============
 
20200817_120430
 
scaler dark run (gain 64) (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 1kV
 
 
20200817_125317
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 1kV
 
 
20200817_162504
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.9kV
 
 
20200817_164237
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.8kV
 
 
20200817_170031
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.85kV
 
 
20200817_175411
 
scaler dark run (gain 32)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.85kV
 
 
20200817_182540
 
scaler dark run (gain 32)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.8kV
 
 
=== reseal box, remove cap on pmt  ============
 
20200817_234649
 
scaler ped run
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV off
 
 
20200817_235949
 
scaler dark run (gain 32) (150 - 250 scan)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 1kV
 
 
20200818_002440
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.8kV
 
 
20200818_005347
 
scaler dark run (gain 64) (step 10)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.8kV
 
 
20200818_010046
 
scaler dark run (gain 64) (step 10)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.8kV, LED 1kHz 5ns 2V
 
 
20200818_012607
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.8kV, LED 1kHz 5ns 2V
 
 
20200818_125138
 
scaler dark run (gain 64) (step 10)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.8kV, LED 1kHz 100ns 3V
 
 
20200818_134121
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
1 PMT at board 3 and asic 0, HV 0.8kV, LED 1kHz 100ns 3V
 
 
=== install all 15 pmt  ============
 
20200825_171640
 
scaler ped run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV off
 
 
20200825_180146
 
scaler dark run (gain 64) (step 10)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.8kv for pmt 11,12,13,21,22,23,24,31,32,33,34
 
LED 1kHz 100ns 3V
 
 
20200825_180641
 
scaler dark run (gain 64) (step 10)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.8kv for pmt 11,12,13,21,22,23,24,31,32,33,34
 
 
20200825_183232
 
scaler dark run (gain 64) (step 10)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.8kv for pmt 11,12,13,21,22,23,24,41,42,43,44
 
 
20200825_185112
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.8kv for pmt 11,12,13,21,22,23,24,41,42,43,44
 
 
20200825_191334
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.8kv for pmt 11,12,13,21,22,23,24,31,32,33,34
 
 
=== use gain map (wrong map) ============
 
 
20200826_045223
 
scaler ped run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV off
 
 
20200826_050207
 
scaler dark run (gain map) (step 10)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV map_850v for pmt 11,12,13,21,22,23,24,31,32,33,34
 
 
20200826_051757
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV map_850v for pmt 11,12,13,21,22,23,24,31,32,33,34
 
 
20200826_134427
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV map_850v for all pmts
 
 
=== light leak fixed ============
 
 
20200827_180343
 
scaler ped run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV off
 
 
20200827_185339
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 1kv
 
 
20200827_200801
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.95kv
 
 
20200827_203915
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.9kv
 
 
20200827_205551
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.85kv
 
 
20200827_211246
 
scaler dark run (gain 64)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.8kv
 
 
20200827_215401
 
scaler ped run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV off
 
 
20200827_221005
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.8kv
 
 
20200827_222934
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.85kv
 
 
20200827_224608
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.9kv
 
 
20200827_232317
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 0.95kv
 
 
20200827_233646
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV 1kv
 
 
20200828_005143
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV map_66fC
 
 
20200828_012415
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV map_98fC
 
 
20200828_014954
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV map_147fC
 
 
20200828_020857
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV map_220fC
 
 
20200828_023024
 
scaler dark run (gain map)
 
all 5 boards (3,4,5,6,7) at fiber 0-4
 
HV map_329fC
 
 
20200918_155713
 
scaler ped run (gain 64)
 
4 boards (3,1,5,6) at fiber 0-3
 
HV map_329fC
 
 
20200918_161900
 
scaler ped run (gain 64)
 
4 boards (3,1,5,6) at fiber 0-3
 
HV off
 
 
20200918_162739
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-3
 
HV off
 
 
=== With LED HV of PMT 6,9,12, and 15 were OFF=====
 
20201119_082042
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 100 ms (10 Hz)
 
 
scaler ped run (gain 64)
 
20201119_082818
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 1 ms (1000 Hz)
 
 
20201119_083545
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 50 us (20 kHz)
 
 
20201119_084102
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 10 us (100 kHz)
 
 
20201119_104115
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 5 us (200 kHz)
 
 
20201119_104216
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 3 us (333 kHz)
 
 
======= With HV for all PMT ON ======
 
20201123_095231
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
No LED
 
 
20201123_100415
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 100 us
 
 
20201123_101059
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 70 us
 
 
20201123_101729
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 50 us
 
 
20201123_102314
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 20 us
 
 
20201123_113347
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 10 us
 
 
20201123_103435
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 5 us
 
 
20201123_110052
 
scaler ped run (gain 64)
 
4 boards (3,4,5,6) at fiber 0-4
 
HV 850 V
 
LED 3 us
 
 
 
 
 
 
 
 
 
 
</pre>
 