Carl test log

From solidwiki
Revision as of 16:24, 7 August 2023 by Zwzhao (Talk | contribs)

Jump to: navigation, search

DAQ use wiener crate and caen 12bit v792 qdc and labview

It has limit near 500hz with 5 channels. There will be deadtime when rate is larger than that

It takes negative signals as input and needs input signal baseline at about -15mV to have adc pedestal at about 200-300 channels

MAPMT H12700-03 with SN HA0011 with simple sum readout (WLS coating removed)

simple sum readout has positive quad and negative sum signal

laser only

  • MAPMT HV=1100V, laser with filter1 1% and filter2 vary, LED off, trigger window 100ns
    • data taking time 100s,laser 2khz
      • 20230731_1909 100%
      • 20230731_1913 80%
      • 20230731_1920 60%
      • 20230731_1923 40%
      • 20230731_1925 20%
    • data taking time 500s,laser 2khz
      • 20230801_1855 100%
      • 20230801_1905 80%
      • 20230801_1914 60%
      • 20230801_1922 40%
      • 20230801_1932 20%
    • data taking time 50s,laser 10khz
      • 20230801_1943 100%
      • 20230801_1944 80%
      • 20230801_1945 60%
      • 20230801_1946 40%
      • 20230801_1948 20%
    • data taking time 10s,laser 10khz
      • 20230803_1425 100%
      • 20230803_1426 80%
      • 20230803_1427 60%
      • 20230803_1428 40%
      • 20230803_1429 20%
    • data taking time 10s,laser 10khz
      • 20230803_1638 100%
      • 20230803_1639 80%
      • 20230803_1640 60%
      • 20230803_1641 40%
      • 20230803_1642 20%
    • data taking time 10s,laser 10khz
      • 20230803_1648 100%
      • 20230803_1649 80%
      • 20230803_1650 60%
      • 20230803_1651 40%
      • 20230803_1652 20%
    • data taking time 10s,laser 10khz
      • 20230803_1756 100%
      • 20230803_1757 80%
      • 20230803_1758 60%
      • 20230803_1759 40%
      • 20230803_1800 20%
    • data taking time 100s,laser 10khz
      • 20230803_1909 100%
      • 20230803_1919 80%
      • 20230803_1921 60%
      • 20230803_1923 40%
      • 20230803_1926 20%


  • MAPMT HV=1100V, laser with filter1 10% and filter2 vary, LED off, trigger window 100ns
    • data taking time 10s,laser 10khz
      • 20230802_1935 100%
      • 20230802_1936 80%
      • 20230802_1937 60%
      • 20230802_1938 40%
      • 20230802_1940 20%
    • data taking time 100s,laser 10khz
      • 20230803_1946 100%
      • 20230803_1948 80%
      • 20230803_1950 60%
      • 20230803_1952 40%
      • 20230803_1955 20%
  • MAPMT HV=1100V, laser 10khz with filter1 vary and filter2 vary, LED off, trigger window 100ns, data taking time 100s
    • 20230804_1245 filter1 100%, filter2 100%
    • 20230804_1247 filter1 100%, filter2 80%
    • 20230804_1249 filter1 100%, filter2 60%
    • 20230804_1257 filter1 100%, filter2 40%
    • 20230804_1259 filter1 100%, filter2 20%
    • 20230804_1308 filter1 10%, filter2 100%
    • 20230804_1311 filter1 10%, filter2 80%
    • 20230804_1314 filter1 10%, filter2 60%
    • 20230804_1317 filter1 10%, filter2 40%
    • 20230804_1325 filter1 10%, filter2 20%
    • 20230804_1331 filter1 1%, filter2 100%
    • 20230804_1334 filter1 1%, filter2 80%
    • 20230804_1344 filter1 1%, filter2 60%
    • 20230804_1347 filter1 1%, filter2 40%
    • 20230804_1349 filter1 1%, filter2 20%
  • MAPMT HV vary, LED off, trigger window 100ns, data taking time 100s
    • laser 10khz with filter1 10% and filter2 40%
      • 20230804_1420 HV 1100V
      • 20230804_1423 HV 1050V
      • 20230804_1425 HV 1000V
      • 20230804_1428 HV 950V
      • 20230804_1430 HV 900V
      • 20230804_1645 HV 850V
      • 20230804_1649 HV 800V
    • laser 10khz with filter1 10% and filter2 80%
      • 20230804_1730 HV 1100V
      • 20230804_1728 HV 1050V
      • 20230804_1725 HV 1000V
      • 20230804_1718 HV 950V
      • 20230804_1712 HV 900V
      • 20230804_1657 HV 850V
      • 20230804_1652 HV 800V

laser + LED

  • MAPMT HV=1100V, laser with filter1 1% and filer2 vary, trigger window 100ns
    • data taking time 100s,laser 2khz, LED on 100khz 5V
      • 20230731_1952 100%
      • 20230731_1956 80%
      • 20230731_1958 60%
      • 20230731_2000 40%
      • 20230731_2002 20%
    • data taking time 50s,laser 10khz, LED on 10khz 3V
      • 20230802_1229 100%
      • 20230802_1233 80%
      • 20230802_1237 60%
      • 20230802_1238 40%
      • 20230802_1239 20%
    • data taking time 10s,laser 10khz, LED on 5000khz 2.5V
      • 20230802_1844 100%
      • 20230802_1846 80%
      • 20230802_1847 60%
      • 20230802_1848 40%
      • 20230802_1849 20%
    • data taking time 10s,laser 10khz, LED on 5000khz 2.5V
      • 20230803_1451 100%
      • 20230803_1452 80%
      • 20230803_1453 60%
      • 20230803_1454 40%
      • 20230803_1455 20%
    • data taking time 10s,laser 10khz, LED on 5000khz 2.5V
      • 20230803_1643 100%
      • 20230803_1644 80%
      • 20230803_1645 60%
      • 20230803_1646 40%
      • 20230803_1647 20%
    • data taking time 100s,laser 10khz, LED on 5000khz 2.5V
      • 20230803_1929 100%
      • 20230803_1931 80%
      • 20230803_1935 60%
      • 20230803_1937 40%
      • 20230803_1939 20%
  • MAPMT HV=1100V, laser with filter1 10% and filer2 vary, trigger window 100ns
    • data taking time 10s,laser 10khz, LED on 5000khz 2.5V
      • 20230802_1942 100%
      • 20230802_1943 80%
      • 20230802_1944 60%
      • 20230802_1945 40%
      • 20230802_1946 20%
    • data taking time 100s,laser 10khz, LED on 5000khz 2.5V
      • 20230803_1959 100%
      • 20230803_2002 80%
      • 20230803_2004 60%
      • 20230803_2006 40%
      • 20230803_2008 20%
  • MAPMT HV=1100V, laser with filter1 1% and filer2 100%, trigger window 100ns
    • data taking time 50s,laser 10khz, LED on 2.3V
      • 20230802_1623 LED 100khz
      • 20230802_1632 LED 500khz
      • 20230802_1635 LED 1000khz
      • 20230802_1636 LED 5000khz
      • 20230802_1659 LED 10000khz
    • data taking time 10s,laser 10khz, LED on 2.5V (sum mu=0.6)
      • 20230802_1832 LED 100khz
      • 20230802_1833 LED 500khz
      • 20230802_1834 LED 1000khz
      • 20230802_1835 LED 5000khz
      • 20230802_1836 LED 10000khz

ped

  • MAPMT, laser off, LED off, trigger window 100ns, data taking time 100s
    • ['20230801_1231', 'ped HV1100+LV, after some lights'],
    • ['20230801_1654', 'ped LV, after some lights'],
    • ['20230804_1118', 'ped HV1100+LV, before any light'],
    • ['20230804_1124', 'ped LV, before any light'],
    • ['20230804_1144', 'ped HV1100+LV after 10min of laser 10khz filter1 1% filter2 100%'],
    • ['20230804_1153', 'ped HV1100+LV after another 10min of laser 10khz filter1 1% filter2 100% + LED 5Mhz 2.5V'],
    • ['20230804_1219', 'ped HV1100+LV after another 20min of laser 10khz filter1 10% filter2 100% + LED 5Mhz 2.5V'],

LED only

  • MAPMT HV=1100V, laser off, LED vary, trigger window 100ns, data taking time 100s (laser trigger)
    • 20230731_1943 LED only 100khz 3V
    • 20230731_1946 LED only 100khz 5V
    • 20230731_1948 LED only 100khz 4V
    • 20230801_1317 LED only 10khz 5V
    • 20230801_1320 LED only 10khz 4V
    • 20230801_1322 LED only 10khz 3V
    • 20230801_1332 LED only 500khz 5V
    • 20230801_1335 LED only 500khz 4V
    • 20230801_1338 LED only 500khz 3V
  • MAPMT HV=1100V, laser off,LED vary, trigger window 100ns, (LED trigger)
    • 20230802_1411 LED only 10khz 2.5V, data taking time 50s
    • 20230802_1444 LED only 10khz 2.3V, data taking time 50s
    • 20230802_1449 LED only 50khz 2.3V, data taking time 10s
    • 20230802_1450 LED only 100khz 2.3V, data taking time 5s
    • 20230802_1615 LED only 500khz 2.3V, data taking time 1s
    • 20230802_1619 LED only 1000khz 2.3V, data taking time 1s
    • 20230802_1620 LED only 5000khz 2.3V, data taking time 1s

MAPMT H8500-03 with SN DA0384 with raw sum readout with WLS coating

this is PMT-D used during 2022-2023 beamtest

raw sum readout has negative quad signals

ped

  • laser off, LED off, trigger window 100ns, data taking time 10s
    • 20230807_1319, ped HV 1000V
    • 20230807_1322, ped HV 950V
    • 20230807_1330, ped HV 900V
    • 20230807_1344, ped HV 900V, after some lights
    • 20230807_1359, ped HV 950V, after some lights
    • 20230807_1400, ped HV 1000V, after some lights
    • 20230807_1632 ped HV 1000V, after 10x amplification using NIM with pedestal adjustment

laser only

  • HV vary, laser 10khz filter1 10%, filter2 vary, LED off, trigger window 100ns, data taking time 100s
    • 20230807_1650, HV 850V, filter2 40%
    • 20230807_1654, HV 850V, filter2 80%
    • 20230807_1656, HV 900V, filter2 40%
    • 20230807_1658, HV 900V, filter2 80%
    • 20230807_1702, HV 950V, filter2 40%
    • 20230807_1706, HV 950V, filter2 80%
    • 20230807_1712, HV 1000V, filter2 40%
    • 20230807_1715, HV 1000V, filter2 80%
    • 20230807_1717, HV 1050V, filter2 40%
    • 20230807_1720, HV 1050V, filter2 80%
    • 20230807_1723, HV 1100V, filter2 40%
    • 20230807_1724, HV 1100V, filter2 80%
  • HV 950V, laser 10khz with filter1 vary and filter2 vary, LED off, trigger window 100ns, data taking time 100s
    • 20230807_1737, filter1 100%, filter2 100%
    • 20230807_1740, filter1 100%, filter2 80%
    • 20230807_1744, filter1 100%, filter2 60%
    • 20230807_1746, filter1 100%, filter2 40%
    • 20230807_1748, filter1 100%, filter2 20%
    • 20230807_1751, filter1 10%, filter2 100%
    • 20230807_1755, filter1 10%, filter2 80%
    • 20230807_1802, filter1 10%, filter2 60%
    • 20230807_1805, filter1 10%, filter2 40%
    • 20230807_1807, filter1 10%, filter2 20%
    • 20230807_1810, filter1 1%, filter2 100%
    • 20230807_1815, filter1 1%, filter2 80%
    • 20230807_1819, filter1 1%, filter2 60%
    • 20230807_1820, filter1 1%, filter2 40%
    • 20230807_1823, filter1 1%, filter2 20%